Carrier - Load and Energy Software ( Paid)

Offered by AHI-CARRIER

Carrier Commercial Australia offers an advanced building load and energy modeling software known as HAPv6, which stands for the Hourly Analysis Program.

https://www.carrier.com/commercial/en/au/hourly-analysis-program/

This powerful tool is specifically designed to meet the needs of consulting engineers, design and construct (D&C) contractors, HVAC contractors, and other professionals involved in the design, analysis, and optimization of commercial building HVAC systems.

 

### What is HAPv6?

 

HAPv6 is a comprehensive software solution that combines two powerful tools in one package: load calculation and energy modeling. These capabilities make it an indispensable resource for professionals working on a wide range of HVAC projects. The software is versatile and supports the design and analysis of various HVAC systems, from small office buildings to large commercial complexes, including variable refrigerant flow (VRF) systems, central air handlers, water source heat pumps, ground source heat pumps, fan coil units, chilled water, and hot water plants.

 

### Key Features of HAPv6

 

One of the standout features of HAPv6 is its ability to model a wide array of HVAC systems and applications. Whether you’re working on a small retail store or a large hospital, the software provides the necessary tools to accurately size and model HVAC systems while performing detailed energy analysis. Key features include:

 

1. **3D Building Modeling**: HAPv6 allows users to create detailed 3D models of buildings, which enhances the accuracy of load and energy calculations. This feature is particularly beneficial when designing complex building structures with multiple zones and varying environmental conditions.

 

2. **System Design**: The software offers extensive system design capabilities, enabling users to create HVAC designs that meet specific building requirements. Whether you are working with variable air volume (VAV) systems, central air handlers, or specialized HVAC configurations, HAPv6 provides the flexibility needed for precise system design.

 

3. **Energy Modeling**: Energy modeling is a critical component of the HAPv6 software. It allows users to evaluate the energy performance of different HVAC systems under various operating conditions. This feature is essential for energy conservation projects, retrofits, and new installations aimed at reducing energy consumption and costs.

 

4. **Load Calculation**: Accurate load calculation is crucial for designing efficient HVAC systems. HAPv6 offers comprehensive load calculation tools that consider various factors, including building orientation, insulation, occupancy, and external weather conditions. This ensures that the HVAC systems are neither over- nor undersized, leading to optimal performance.

 

5. **Climate Analysis**: The software includes tools for analyzing climate data, which is vital for designing HVAC systems that can handle the specific weather conditions of the building’s location. This ensures that the system operates efficiently throughout the year.

 

6. **Air System Analysis**: HAPv6 provides detailed analysis tools for air distribution systems, allowing users to optimize airflows, ductwork, and ventilation strategies. This is particularly useful for projects involving complex air distribution networks.

 

7. **Plant Equipment Modeling**: Users can model and analyze various types of plant equipment, including boilers, chillers, and cooling towers, to ensure that the selected equipment meets the building’s heating and cooling demands efficiently.

 

8. **Utility Rates and Cost Analysis**: The software includes features for analyzing utility rates, helping users estimate the operating costs of different HVAC systems. This is beneficial for making informed decisions about system selection based on both performance and cost.

 

### Applications of HAPv6

 

HAPv6 is suitable for a wide range of applications, from small office buildings to large commercial buildings, such as shopping centers, hotels, hospitals, and factories. The software’s flexibility makes it ideal for both new installations and retrofit projects, as well as energy conservation initiatives. Typical applications include:

 

- **Small to Large Commercial Buildings**: From small offices to expansive shopping centers, HAPv6 handles the complexities of various building types.

- **Variable Refrigerant Flow (VRF) Systems**: The software’s ability to model VRF systems makes it a valuable tool for projects requiring flexible HVAC solutions.

- **Central Air Handlers and Heat Pumps**: HAPv6 supports the design and analysis of central air handling units, water source heat pumps, and ground source heat pumps.

- **Fan Coil Units and Chilled Water Plants**: The software’s comprehensive modeling capabilities extend to fan coil units and chilled water systems, ensuring accurate system sizing and energy analysis.

 

### Why Choose HAPv6?

 

For professionals involved in the design and analysis of commercial building HVAC systems, HAPv6 offers a one-stop solution that simplifies the process of load calculation and energy modeling. The software’s integrated approach ensures that all aspects of HVAC design and analysis are covered, making it easier to achieve efficient, cost-effective, and high-performance systems. Additionally, Carrier Commercial Australia provides extensive resources, including a brochure and instructional video, to help users maximize the software’s potential.

 

In conclusion, Carrier’s HAPv6 is more than just a software program—it’s a powerful tool that empowers HVAC professionals to design, analyze, and optimize building systems with precision and confidence. Whether you are working on a small office renovation or a large-scale commercial development, HAPv6 provides the insights and capabilities needed to achieve success. To learn more about HAPv6 and explore its full range of features, visit the Carrier Commercial Australia website and download the brochure today.

 

 

 

Tools/Calculators